Message: [time-nuts] Setting Trimble Thunderbolt Stored Position

Short answer: go to Setup→Self-Survey, make sure the Enable and Save buttons are clicked, then hit “Set Survey,” “Save Segment,” and “Close.” After that, do a Control→Restart Self-Survey. The alarm indication should go away once the survey process finishes.

You do not need to copy anything manually unless you want to specify a more-accurate survey position than what the Thunderbolt arrives at on its own.

– john, KE5FX

 